8.3 The outside can be wiped with a clean towel. Test your alarms weekly and repair or replace them when
they no longer function. As with any electronic product, it has a limited life. Alarms that do not work cannot warn
you.
8.4 After cleaning, reinstall your alarm and test your alarm by using the TEST button.
! WARNING: Do not use any household cleaning agents, paints, varnishes or any other chemical on your 9RV
alarm.
NOTE: REGULAR TESTING IS RECOMMENDED.
9.0 BATTERY REPLACEMENT
IF TAMPER RESISTANT PIN HAS BEEN USED, REFER TO STEP 6.7 UNDER INSTALLATION
INSTRUCTIONS FOR REMOVAL INSTRUCTIONS. (see Figure 3)
9.1 To replace the battery remove the alarm from the mounting plate by rotating the alarm in the direction of
the "OFF" arrow on the cover. (see Figure 2, Step D).
9.2 The COSTAR
®
Model 9RV CO Alarm uses one (1) 9 volt alkaline battery. A fresh battery should last for
one year under normal operating conditions. They can be purchased anywhere batteries are sold, such as your local
hardware store.
9.3 USE ONLY THE FOLLOWING 9 VOLT BATTERY FOR CO ALARM REPLACEMENT.
Alkaline type: DURACELL MN1604
! WARNING!! USE ONLY THE BATTERY SPECIFIED. USE OF DIFFERENT BATTERIES MAY HAVE A
DETRIMENTAL EFFECT ON THE CO ALARM. CONSTANT EXPOSURE TO HIGH OR LOW HUMIDITY
MAY REDUCE BATTERY LIFE.
CHECK THE BATTERY MANUFACTURERS SPECIFICATIONS FOR PROPER OPERATING CONDITIONS.
Note: Most batteries are not rated below -20°C or above 54°C
10.0 PERIODIC ALARM TESTING
Test the alarm weekly for proper operation by pushing the test button until a short beep is heard (approximately
three seconds). Release the button.
The alarm will then test itself for proper operation and the RED L.E.D. light will flash 4-6 times. At completion of
the self-test, the alarm will sound 2 patterns. The alarm then resumes normal operation.
11.0 SERVICE AND WARRANTY
If after reviewing this manual you feel that your CO Alarm is defective in any way, do not tamper with the unit.
Before returning your device, call Quantum Group's customer service line at 1-800-432-5599 to receive a return
merchandise authorization (RMA) number. Once an RMA number has been issued, return product along with proof
of purchase that includes a date. Please enclose a note describing the problem and send it to:
7737 Kenamar Court
San Diego, CA 92121-2425
Or call us toll free 1-800-432-5599
E-mail address: Cust[email protected]
Seitenansicht 5
1 2 3 4 5 6 7

Kommentare zu diesen Handbüchern

Keine Kommentare